Server room cooling in Harlow
Almost every watt your IT draws ends up as heat, and a small closed room gets hot fast. We fit server room and comms cupboard cooling for businesses in Harlow and the towns nearby. A correctly sized system holds the temperature steady all year, so your network stays up.
Ask for a server room quote
Your name, number and postcode. We ring you back.
- Worked out from your IT load
- Runs all day, all year
- A second unit if you need one
Harlow's data centres, and the smaller rooms we cool
Charles Kao developed optical fibre data transmission on the eastern edge of Harlow, at the site Nortel later occupied, and the Kao Data campus on London Road is a £200m development using indirect evaporative cooling. Places like that employ their own engineers. We work at the other end of the scale: the comms cupboard in an office, the small server room in a factory or surgery, the one nobody thinks about until it fails.
How much cooling does a small room need?
Begin with the electrical load, because a server drawing 900W is also a 900W heater. Total up each server, switch, router and storage box. Allow for lights, people, any sunny window and future growth. Your UPS may display the load directly, and that is the most useful figure you can send us.
What temperature should a server room be?
The widely used ASHRAE guideline recommends 18°C to 27°C where air enters the rack, and UPS batteries tend to prefer the cooler end. There is no prize for going lower. A room held at 18°C when the equipment would be fine at 24°C is only using more energy. Take readings at the rack front, because a wall controller can be several degrees out.
Can you use a standard office unit?
Sometimes, but the duty differs in three ways. It runs every day, so it wears faster. It must still cool in January, when highs at the Writtle climate station average about 8°C and frost is common, and some models will not run reliably in that. And nobody is in the room, so a failure on Friday night might go unseen until Monday. Ask about the low outdoor temperature limit, and add a separate temperature alarm whatever you choose.
Do you need back-up cooling?
You do if losing the room would stop the business. The usual answer is a second unit ready to take over, and two units can also alternate, sharing the wear and keeping cover during a service. At the very least, write down what happens in the first few hours. Portable units make a poor long-term plan, given the exhaust hose through a door and the tank to empty.
Questions people ask
How quickly does a comms room overheat?
That depends on the load and the room, but several kilowatts of IT in a small closed space warms up fast once the cooling stops. An alarm buys you time.
Do you have to shut anything down?
Your IT can normally stay up during the fitting. A new circuit might need the power off for a while in part of the building, at a time we would agree.
Is this caught by the 12kW inspection rule?
It may. GOV.UK's guidance leaves out dedicated process cooling but says cooling for IT that also benefits the people using the space counts. An energy assessor can tell you.
Sources
Useful to have ready
A few details about the building let us say more on the first call.
- Your postcode
- House, flat or business premises
- Which rooms, and roughly how big
- Which way the windows face
- Who owns the outside walls, if you rent or lease
Server room cooling beyond Harlow
Looking for server room cooling outside Harlow? We go to the towns below, and each page has its own planning points. For everything we offer, begin with air conditioning in Harlow.
Worth reading first
What size air conditioner do you need?
Floor area, kW and BTU, and what shifts the answer.
How to check an installer's F-gas certificate
Two certificates worth asking for, plus leak checks and refrigerant bans.
How much does air conditioning cost?
Every cost from purchase to running it, with the working shown.
Related work
Office air conditioning
From one room over a workshop to a full floor.
Commercial air conditioning
For shops, salons, cafes, gyms and surgeries.
More from Harlow Air Conditioning
Air conditioning installation
The whole job, stage by stage, from first visit to handover.
Domestic air conditioning
For the bedroom that stays hot after dark, and rooms like it.
Air-to-air heat pumps
One unit for winter warmth and summer cooling. No radiators.
Multi-split air conditioning
Several indoor units on a single outdoor unit.
Conservatory air conditioning
For rooms that bake in July and freeze in January.
Air conditioning servicing
A yearly clean and check, whoever fitted the system.
Air conditioning repairs
Drips, weak cooling, fault codes and dead units.
Ask us to ring you
Leave a number and we will call to talk about the job. Or ring 01279 744503.